Explosion-proof electric linear actuator MT-Ex

Type number: | 52 410 | |
Switching-off thrust: | 4800 to 36000 | [N] |
Operating speed: | 32 to 180 | [mm/min] |
Operating stroke: | 10 to 100 | [mm] |
Ambient temperature: | -20 to +55 | [°C] |
Protection enclosure: | IP 54 | |
Operating position: | the motor axis should be in horizontal position +/-15° |
|
Weight: | 52,5 to 55 | [kg] |
Explosion protection: | II 2G Ex de IIB T5 II 2G c IIB T5 |
Standard equipment
- Supply voltage 230 V AC, 3×400 V AC
- Terminal board connection
- 2 thrust switches
- 2 position switches
- 2 additional position switches
- Space heater
- Mechanical connection – pillars
- Manual control
- Protection code IP 54
Additional equipment
- Supply voltage 3×380 V AC
- Transmitter:
– potentiometer: 1×100 Ω, 2×100 Ω - Mechanical connection – flange
– CPT (capacitive) 4 – 20 mA, passive